NTI IPDU-S2 Secure Remote Power Control Unit with Environmental Monitoring
NTI IPDU-S2 Secure Remote Power Control Unit with Environmental Monitoring allows you to remotely reboot and control power (on/off) to up to eight servers or other powered devices from any location via secure web interface, RS232, SSH, or Telnet.
NTI IPDU-S2 Secure Remote Power Control Unit with Environmental Monitoring Features:
- Three operating modes for power reboot:
- Manual - select the outlet and turn the power on/off.
- Scheduled - set date/time/duration of power cycle.
- Associated - power on/off a device when a sensor goes out of range of a user-defined threshold, or reboot unresponsive IP devices.
- Security: HTTPS, SSHv2, SSLv3, TLS (4/8-port models only), IP Filtering, LDAPv3, AES 256-bit encryption, 16-character username/password authentication, user account restricted access rights.
- Configure, control and monitor the unit via Web interface or Command Line Interface (CLI).
- Up to 3 additional IP aliases can be configured to allow remote control of the unit using different networks.
- No scripts required - simply add the IP address, network mask, and gateway configurations through the web interface.
- The first network (default network) will be used for total control of the unit, i.e. inbound and outbound connections.
- The three other networks will allow web/SSH/telnet access only, i.e. inbound access only.
- Up to four separate networks can be plugged into a network switch that is linked to the unit to facilitate the configuration.
- Current, line voltage, line frequency, power factor monitoring (4/8-port models only).
- Supports two environmental sensors, including: temperature/humidity and water detection.
- Shut down power when high temperature and other environmental threats are detected.
- Monitor (ping) up to eight IP network devices.
- Sends alert notifications via email, syslog, LEDs, Web page, and SNMP.
- Automatically configures network settings received from a connected DHCP server.
- If a DHCP server is not found, the default static IP address will be used.
- Integrates with various Open Source monitoring packages - Nagios and MRTG.
- The unit can be polled via SNMP.
- Up to 17 units can be connected via Ethernet connection or using CAT5 expansion cables to increase the number of outlets and sensors connected (4- and 8-port models only).
- Cascade up to 16 IPDU-Sx units as slaves to one IPDU-Sx master unit via Ethernet connection.
- Each master and slave unit needs its own unique IP address.
- Cascade up to 16 IPDU-Sx units as slaves to one IPDU-Sx master unit using CAT5/5e/6 patch cables with RJ45 connectors wired straight through.
- Each slave unit needs its own unique RS485 address value that can range from 1-255.
- Uses a single Web interface for all systems/sensors connected.
- Cascade up to 16 IPDU-Sx units as slaves to one IPDU-Sx master unit via Ethernet connection.
- Overload protection via circuit breaker (4/8-port models only).
- Optional intuitive graphical management software< provides an easy-to-use, unified interface for both monitoring and configuring up to 3,000 E-2D/5D/16D, E-SEMS-16(U), IPDU-S4/8 units and all connected sensors.
- Meets the electrostatic discharge (ESD) immunity requirements of IEC/EN 61000-4-2
- Features Normally Open (NO) relay contacts.
- The 4/8-port units are available with optional Normally Closed (NC) relaycontacts.
- Optional industrial unit for harsh environments at temperatures from -40˚ to 158˚F (-40˚ to 70˚C).
Why not buy this NTI IPDU-S2 Secure Remote Power Control Unit with Environmental Monitoring today?
NTI IPDU-S2 Secure Remote Power Control Unit with Environmental Monitoring Specification:
Power- 90 to 250 VAC at 50 to 60 Hz.
- Two RJ45 modular jacks for connecting NTI temperature/humidity and liquid detection sensors.
- Available sensors
- One 10/100 Base-T Ethernet port with RJ45 Ethernet connector.
- One female RJ45 port for terminal access.
- Two RJ45 jacks.
- A maximum of 17 systems can be used in a cascaded configuration via RS485 to increase the number of outlets and sensor ports (1 master, 16 slaves).
- Each slave unit needs its own unique RS485 address value that can range from 1-255.
- Use CAT5/5e/6 patch cables with RJ45 connectors wired straight through
- Up to 1,000 feet between the master unit and the slave unit.
- The last slave must have a terminating plug (E-TRMPLG, not included) in the empty socket.
- Female USB Type A connector for downloading log data to USB flash drive.
- 6.12x5.55x1.4
- Operating temperature: 32 to 122˚F (0 to 50˚C).
- Storage temperature: -13 to 149˚F (-25 to 65˚C).
- 183,724
- HTTPS, SSHv2, SSLv3, TLS (4/8-port models only), LDAPv3, AES 256-bit, 3DES, Blowfish, RSA, EDH-RSA, Arcfour, SNMPv2c; IP filtering, IPV6
- Operates and configures via HTTP/HTTPS web page, Telnet, SSH, or RS232 interface.
- Alerts are sent using email, syslog, and/or SNMP traps.
- Alerts are posted in event log, which is accessible through Web user interface.
- CE, RoHS
- EN51055, EN50121-3-2
- Two years
Data Sheet: NTI IPDU-S2 Data Sheet
Users Manual: NTI IPDU-S2 Installation Manual
How To:
Reasons To Buy an NTI Product