NTI E-LD100-20 Liquid Detection Sensor, Cable 100ft 2-Wire Cable 20ft

NTI

$1,132.00

5% Discount. Apply Code 5percentOff at Checkout!

Part Number:
E-LD100-20
Availability:
In Stock
1:
For Detecting Water Presence & Warning of Flooding
2:
100% Waterproof Electronics
3:
Detects Any Conductive Liquid or Moisture
4:
Free 15-Day Trial (See below FAQ)
5:
Free Shipping
6:
2-Year NTI Warranty
ADD OPTIONS:
NTI E-LD100-20 Liquid Detection Sensor, Plenum Rope-Style - Length of water sensor cable - 100 ft. Length of 2-wire cable - 20 ft.

This NTI E-LD100-20 Liquid Detection Sensor, Plenum Rope-Style - Length of water sensor cable - 100 ft. Length of 2-wire cable - 20 ft. Connect the liquid detection sensor E-LD (E-LDx-y, E-LD-LCx-y, E-CDx-y) to a set of terminals (1-5) marked "DIGITAL IN". The twisted orange sensing cable should be placed flat on the surface (usually the floor) where liquid detection is desired. If tape is required to hold the sensor in place, be sure to only apply tape to the ends, exposing as much of the sensor as possible. At least 5/8" of the sensor must be exposed for it to function.

NTI E-LD100-20 Liquid Detection Sensor, Plenum Rope-Style - Length of water sensor cable - 100 ft. Length of 2-wire cable - 20 ft. Features:

  • For detecting water presence and warning of flooding.
  • 100% waterproof electronics.
  • Detects any conductive liquid or moisture.
  • Minimum puddle: 0.6" (15 mm) diameter.
  • Detects liquid depth >0.1" (2.5 mm).

Why not buy this NTI E-LD100-20 Liquid Detection Sensor, Plenum Rope-Style - Length of water sensor cable - 100 ft. Length of 2-wire cable - 20 ft. today?

NTI E-LD100-20 Liquid Detection Sensor, Plenum Rope-Style - Length of water sensor cable - 100 ft. Length of 2-wire cable - 20 ft. Specifications:

  • Voltage and current:
    • Open Circuit: 5VDC max @ 1µA.
    • Closed circuit: <300mV @ 10.7mA.
  • Available water sensor cable (x) lengths: 1/10/50/100/200/400/600/800/1000 feet.
    • Plenum rating: CL2P (UL)
    • Diameter: 0.25 in (6.35mm)
    • Bend radius: 0.375 in (9.53 mm)
    • Operating temperature: 32 to 167°F (0 to 75°C).
  • Available 2-wire plenum cable (y) lengths: 5/10/20/50/100 feet.
    • Insulation and Outer Jacket Material: Plenum Grade PVC
    • Diameter: 0.111 in (2.82 mm)
    • Contact an NTI product consultant for cable lengths over 100 feet (30 meters) - supports up to 1,000 feet (305 meters).
  • Regulatory approvals: CE, RoHS
  • MTBF: 10,869,188 hrs
  • Use self-adhesive clips (E-CLPxx-LD) to prevent sensor rope cable from shifting after installation

Why not buy this NTI E-LD100-20 Liquid Detection Sensor, Plenum Rope-Style - Length of water sensor cable - 100 ft. Length of 2-wire cable - 20 ft. today?

E-LD100-20 User Manual

Why not buy this NTI E-LD100-20 Liquid Detection Sensor, Plenum Rope-Style - Length of water sensor cable - 100 ft. Length of 2-wire cable - 20 ft. today?

Frequently Asked Questions
Reasons To Buy an NTI Product