NTI E-ACLM-P18-V2 AC Power Monitor with Relay

NTI

$412.00
Part Number:
E-ACLM-P18-V2
Availability:
In Stock
1:
Reports AC Voltage, Frequency and Current
2:
Auto-Configured Upon Connection With E-xD
3:
AC Power Monitor with Relay
4:
Free 15-Day Trial (See below FAQ)
5:
Free Shipping
6:
2-Year NTI Warranty
ADD OPTIONS:
NTI E-ACLM-P18-V2 AC Power Monitor with Relay

NTI E-ACLM-P18-V2 AC Power Monitor with Relay is a sensor for the E-16D/5D/2D systems (ENVIROMUX) capable of monitoring AC line input voltages and frequencies between 50~250V AC and 47~63Hz from two separate AC lines. It will report the current RMS AC Voltage and AC Frequency (Hertz) to the E-xD. The ACLM-V will also monitor the number of short term Swells1 and Sags2 as well as the number of Spikes3.

The ACLM-V utilizes two UL certified IEC 320 C14 inlets to connect to the AC lines being monitored. The ACLM-V connects to the ENVIROMUX through up to 1,000 ft of CAT5/5e/6 cable. Data is transmitted to and from the ENVIROMUX using the RS485 protocol.

NTI E-ACLM-P18-V2 AC Power Monitor with Relay Features:

  • 12 bit ADC resolution, 1% full scale ADC accuracy
  • Measure AC Voltage (1% @25°C accuracy) and AC Frequency (1% accuracy)
  • Monitors swells, sags, and spike events
  • Auto-Configured upon connection with E-xD
  • RJ45 Status LED's for operating status
  • User selectable data interpolation options

Why not buy this NTI E-ACLM-P18-V2 AC Power Monitor with Relay today?

NTI E-ACLM-P18-V2 AC Power Monitor with Relay Specifications:

  • Reports AC Voltage, Frequency, Power, and Current.
    • Monitors Power from one AC inlet to one AC outlet, between 50~250VAC and 47~63Hz.
    • Monitors the number of swells, sags, and spikes.
      • Monitors swell and sag duration of 0.1 second to 1 minute.
  • Includes Relay with configurable disconnect settings: threshold reboot, or manual reboot.
  • Accuracy
    • Voltage accuracy: ±1% FS at 32 to 104°F (0 to 40°C).
    • Frequency accuracy: ± 1%
    • Current accuracy: ± 2.7%
  • Outlet Max load rating (continuous):
    • E-ACLM-P18-V2 (US/Canada): 18A rated load, 20A maximum.
    • E-ACLM-P12-V2 (US/Canada): 12A rated load, 15A maximum.
    • E-ACLM-P8-V2 (Euro/UK): 8A rated load, 10A maximum.
  • Capable of measuring current surges from 300 mA to 20A.
  • User defined minimum and maximum voltage and power thresholds.
  • Capable of detecting user selected spike events with a peak greater than 50V, 250V, 500V, or 1KV.
  • Cables included:
    • E-ACLM-P12/8-V2: one country-specific IEC 320 C13 line cord, and one IEC 320 C14 to IEC 320 C13 cord set for connection to AC load.
    • E-ACLM-P18-V2: one L6-20r to IEC 320 C20, and one L6-20p to IEC 320 C19.
  • Supports CAT5/5e/6 cable up to 1,000 ft. (305 m).
    • E-2D/5D: supports CAT5/5e/6 cable up to 750 ft (229 m).
  • Dimensions (WxDxH) in:
    • E-ACLM-P12/8-V2: 7.0x5.5x1.65 (178x140x42 mm).
    • E-ACLM-P18-V2: 7.0x6.5x1.65 (178x165x42 mm).
  • Weight: 1.6 lbs (726 g).
  • Current consumption: 13mA @ 5VDC, 125mA @ 12VDC.
  • Powered by E-2D/5D/16D.
  • Regulatory approvals: CE, RoHS
  • Compatible with E-FSC Fiber Converter/Extender.
    • Use to extend sensor up to 1.2 miles (2 km) from the ENVIROMUX unit.