NTI E-ACLM-P12-V2 AC Power Monitor with Relay is a sensor for the E-16D/5D/2D systems (ENVIROMUX) capable of monitoring AC line input voltages and frequencies between 50~250V AC and 47~63Hz from two separate AC lines. It will report the current RMS AC Voltage and AC Frequency (Hertz) to the E-xD. The ACLM-V will also monitor the number of short term Swells1 and Sags2 as well as the number of Spikes3.
The ACLM-V utilizes two UL certified IEC 320 C14 inlets to connect to the AC lines being monitored. The ACLM-V connects to the ENVIROMUX through up to 1,000 ft of CAT5/5e/6 cable. Data is transmitted to and from the ENVIROMUX using the RS485 protocol.
NTI E-ACLM-P12-V2 AC Power Monitor with Relay Features:
- 12 bit ADC resolution, 1% full scale ADC accuracy
- Measure AC Voltage (1% @25°C accuracy) and AC Frequency (1% accuracy)
- Monitors swells, sags, and spike events
- Auto-Configured upon connection with E-xD
- RJ45 Status LED's for operating status
- User selectable data interpolation options
Why not buy this NTI E-ACLM-P12-V2 AC Power Monitor with Relay today?
NTI E-ACLM-P12-V2 AC Power Monitor with Relay Specifications:
- Reports AC Voltage, Frequency, Power, and Current.
- Monitors Power from one AC inlet to one AC outlet, between 50~250VAC and 47~63Hz.
- Monitors the number of swells, sags, and spikes.
- Monitors swell and sag duration of 0.1 second to 1 minute.
- Includes Relay with configurable disconnect settings: threshold reboot, or manual reboot.
- Accuracy
- Voltage accuracy: ±1% FS at 32 to 104°F (0 to 40°C).
- Frequency accuracy: ± 1%
- Current accuracy: ± 2.7%
- Outlet Max load rating (continuous):
- E-ACLM-P18-V2 (US/Canada): 18A rated load, 20A maximum.
- E-ACLM-P12-V2 (US/Canada): 12A rated load, 15A maximum.
- E-ACLM-P8-V2 (Euro/UK): 8A rated load, 10A maximum.
- Capable of measuring current surges from 300 mA to 20A.
- User defined minimum and maximum voltage and power thresholds.
- Capable of detecting user selected spike events with a peak greater than 50V, 250V, 500V, or 1KV.
- Cables included:
- E-ACLM-P12/8-V2: one country-specific IEC 320 C13 line cord, and one IEC 320 C14 to IEC 320 C13 cord set for connection to AC load.
- E-ACLM-P18-V2: one L6-20r to IEC 320 C20, and one L6-20p to IEC 320 C19.
- Supports CAT5/5e/6 cable up to 1,000 ft. (305 m).
- E-2D/5D: supports CAT5/5e/6 cable up to 750 ft (229 m).
- Dimensions (WxDxH) in:
- E-ACLM-P12/8-V2: 7.0x5.5x1.65 (178x140x42 mm).
- E-ACLM-P18-V2: 7.0x6.5x1.65 (178x165x42 mm).
- Weight: 1.6 lbs (726 g).
- Current consumption: 13mA @ 5VDC, 125mA @ 12VDC.
- Powered by E-2D/5D/16D.
- Regulatory approvals: CE, RoHS
- Compatible with E-FSC Fiber Converter/Extender.
- Use to extend sensor up to 1.2 miles (2 km) from the ENVIROMUX unit.
Why not buy this NTI E-ACLM-P12-V2 AC Power Monitor with Relay today?