NTI E-5D-IND48VLT Industrial Medium Enterprise Environment Monitoring System for Low/High Temperature Environments -40 to 185˚F (-40 to 85˚C), 48VDC Power
NTI E-5D-IND48VLT Industrial Medium Enterprise Environment Monitoring System (EMS) monitors critical environmental conditions, such as temperature, humidity, liquid water presence, power, intrusion, and smoke. When a sensor goes out of range of a configurable threshold, the system will notify you via email, LEDs, alarm beacon, siren, web page, network management (SNMP), voice phone calls (via Automatic Voice Dialer System), and SMS messages (via external USB 3G modem).
The system includes two internal sensors: temperature and humidity. It also supports five external configurable sensors, five digital input sensors, and two output relays for control of external devices.
NTI E-5D-IND48VLT Industrial Medium Enterprise Environment Monitoring System for Low/High Temperature Environments -40 to 185˚F (-40 to 85˚C), 48VDC Power Features:
- Monitor and manage server room environmental and security conditions over IP.
- Sensors supported:
- 5 external configurable sensors
- 5 digital inputs sensitive to contact closure
- 2 internal sensors - temperature and humidity
- 8 Remote Temperature/Humidity Sensors over IP
- E-MICRO-T: 1 integrated temperature sensor, 2 RJ45 ports for external temperature/humidity sensors, 2 digital inputs sensitive to contact closure, dual DC power (dual redundancy).
- E-MICRO-TRHP: 1 integrated temperature/humidity combination sensor, 2 RJ45 ports for external temperature/humidity sensors, 2 digital inputs sensitive to contact closure, built-in Power over Ethernet (POE), dual DC power (triple redundancy).
- 4 Remote 1-Wire Sensors over IP
- E-1W(P): two RJ11 connectors for daisy-chaining many 1-wire temperature/humidity/dew point, thermocouple, or digital input expanders in any combination (up to 24 single-reading 1-wire sensors); two digital inputs sensitive to contact closure; dual DC power; optional Power over Ethernet (POE).
- Two output relays for control of external devices.
- Relay activates upon alarm or via the user interface.
- Control output relays via SNMP SET commands to power on/off external devices.
- Supports IP network video cameras for live view of any facility.
- One integrated view - see different Web cameras side-by-side with physical and environmental parameters.
- Any programmed event can trigger a snapshot from an IP camera.
- Monitor (ping) up to 64 IP network devices.
- Alerts are sent if devices are not responding
- Linux inside.
- Create multiple alerts for any installed sensor.
- Sensor conditions (events) can be configured to trigger alerts by themselves, and/or be used in combination with other events to trigger Smart Alerts.
- Configure up to 50 events.
- Setup SSH commands to be sent when events are triggered to soft shutdown or reboot machines.
- Up to 20 Smart Alerts can be configured to use different event combinations to send alert messages.
- Configure up to 50 events.
- Alerts are posted in message log, which is accessible through Web user interface.
- Automatically configures network settings received from a connected DHCP server.
- If a DHCP server is not found, the default static IP address will be used.
- Integrates with various Open Source monitoring packages - Nagios and MRTG.
- The unit can be polled via SNMP.
- USB ports for connecting USB modem or for downloading log data to USB flash drive.
- Available with optional internal battery backup.
- Alerts are sent when there is a power outage and when power returns.
- Dual redundant power supplies for connection to two separate power sources
- The second power supply is sold separately.
- Available with optional 48VDC power
- Comes with a 48V DC-DC power converter built inside the unit.
- Up to five units can be used together to increase the number of sensors connected.
- Cascade up to four E-2D/5D/16D units as slaves to one E-2D/5D/16D master unit via Ethernet connection.
- Each master and slave unit needs its own unique IP address.
- Uses a single Web interface for all systems/sensors connected.
- Cascade up to four E-2D/5D/16D units as slaves to one E-2D/5D/16D master unit via Ethernet connection.
- Optional industrial medium environment monitoring systems for harsh environments with low/high temperatures from -40 to 185˚F (-40 to 85˚C).
- Industrial model with backup battery: 32 to 140˚F (0 to 60˚C)
- Optional intuitive graphical management software provides an easy-to-use, unified interface for both monitoring and configuring up to 3,000 E-2D/5D/16D, E-SEMS-16(U), IPDU-S4/8 units and all connected sensors.
- Flexible Zero-RU mounting.
- Mounting tabs included.
- Optional DIN mounting available.
- Optional 1RU rackmount kit available; the ENVIROMUX unit can be mounted with the front (sensor connector side) or rear (additional status LEDS with alarm test/silence button side) facing out.
- Security: HTTPS, SSHv2, SSLv3, IP Filtering, LDAPv3, AES 256-bit encryption, 16-character username/password authentication, user account restricted access rights.
- Multi-language support - English, German, Chinese, and Japanese.
- Use in data centers, co-lo sites, web hosting facilities, telecom switching sites, POP sites, server closets, or any unmanned area that needs to be monitored.
Why not buy this NTI E-5D-IND48VLT Industrial Medium Enterprise Environment Monitoring System for Low/High Temperature Environments -40 to 185˚F (-40 to 85˚C), 48VDC Power today?
NTI E-5D-IND48VLT Industrial Medium Enterprise Environment Monitoring System for Low/High Temperature Environments -40 to 185˚F (-40 to 85˚C), 48VDC Power Specification:
RJ45 Sensor Ports- Five RJ45 modular jacks for connecting NTI temperature, humidity, temperature/humidity, liquid detection, smoke detection, glass break, vibration and motion sensors.
- Two levels of user-defined alerts - non-critical and critical.
- Provides +12 VDC, 100 mA for each port
- Five screw terminal pairs for connecting dry contact devices.
- Potential-free
- Input voltage: 0VDC to +25VDC
- Over-voltage surge protection
- Maximum resistance to close contact: 300K Ohm
- Two screw terminals pairs.
- Potential-free relay switch contacts.
- Normally open / normally closed connection points.
- Maximum switching load: 0.5A at 125VAC, 1A at 30VDC, 0.5A at 48VDC.
- One screw terminal pair.
- Provides +12VDC, 180 mA to supply an alarm beacon or siren.
- Fuse protection
- One screw terminal pair.
- Provides +12 VDC, 500 mA.
- One RJ45 port for connecting a serial GSM modem or a remote serially-controlled device.
- Four female USB Type A connectors for connecting USB modem or for downloading log data to USB flash drive.
- One female USB Type B connector for connecting a PC for serial terminal access.
- One 10/100 Base-T Ethernet port with RJ45 Ethernet connector.
- Supports full- and half-duplex.
- Dual DC power.
- If the first power source fails, the unit will automatically, without interruption, switch over to the second power source before switching to the optional battery backup.
- Input: 100 to 240 VAC at 50 or 60 Hz via AC adapter.
- Includes one country-specific AC adapter. The second AC adapter is sold separately.
- Output: 9 VDC, 3A
- Power Consumption: 15W
- Optional 48VDC power.
- E-5D-IND48VLT-48V
- Accepts 18~72VDC (48VDC nominal).
- For installation in a 48V or 24V Telecom environment.
- E-5D-IND48VLT-IND48VLT
- Accepts 36~72VDC (48VDC nominal).
- For installation in a 48V Telecom environment.
- E-5D-IND48VLT-48V
- Use the PWR-48V-12V1-6A DC-DC power converter to install all other E-5D-IND48VLT units in a 48V or 24V Telecom environment.
- E-5D-IND48VLTB-IND requires the
PWR-48V-12V1-6A-55x25 DC-DC power converter.
- E-5D-IND48VLTB-IND requires the
- E-5D-IND48VLT: 170,344 hours.
- E-5D-IND48VLTB: 169,279 hours.
- E-5D-IND48VLT-48V: 151,947 hours.
- HTTP/HTTPS, SNMP V1/V2c/V3, SMTP, TCP/IP, Syslog, SNTP, DHCP, SSHv2, SSLv3, TLS v1.2, LDAPv3, XOAUTH2, AES 256-bit, 3DES, Blowfish, RSA, EDH-RSA, Arcfour, IPV6, WAP 2.0, RADIUS
- Support for XOAUTH2 provides higher security authentication for email accounts (e.g. Gmail).
- Compatible with any SNMP management software.
- The unit can be polled via SNMP.
- Operates and configures via HTTP/HTTPS web page, Telnet, SSH, or USB/RJ45 serial interface.
- An IP address can be assigned to the E-5D-IND48VLT automatically by a DHCP server.
- Generates SNMP traps, email alerts, syslog messages, and SMS messages (via USB 3G modem).
- Alerts are posted in event log, which is accessible through Web user interface.
- Email alerts can be sent to 17 addresses.
- Users can configure the schedule for when they will be alerted, as well as customize the e-mail subject line for each sensor alert.
- SNMP traps have unique OID's (Object Identifiers) for each sensor.
- Applications from:
- E-5D-IND48VLT: 32 to 140˚F (0 to 60˚C), ±0.72˚F (±0.40˚C)
- E-5D-IND48VLTB: 32 to 104˚F (0 to 40˚C), ±0.72˚F (±0.40˚C)
- E-5D-IND48VLTB-IND: 32 to 140˚F (0 to 60˚C), ±0.72˚F (±0.40˚C)
- E-5D-IND48VLT-INDLT/IND48VLT: -40 to 185˚F (-40 to 85˚C)
- Accuracy:
- ±1.62˚F (±0.90˚C) for -40 to 14˚F (-40 to -10˚C).
- ±0.72˚F (±0.40˚C) for 14 to 185˚F (-10 to 85˚C).
- Accuracy:
- Applications from:
- E-5D-IND48VLT: 20% to 80% relative humidity at 32 to 140˚F (0 to 60˚C), ±3%
- E-5D-IND48VLTB: 20% to 80% relative humidity at 32 to 104˚F (0 to 40˚C), ±3%
- E-5D-IND48VLTB-IND: 20% to 80% relative humidity at 32 to 140˚F (0 to 60˚C), ±3%
- E-5D-IND48VLT-INDLT/IND48VLT: 15 to 90% relative humidity at -40 to 185˚F (-40 to 85˚C)
- Accuracy:
- 15 to 80% relative humidity, ±3%
- 80 to 90% relative humidity, ±4%
- Accuracy:
- WxDxH:
- E-5D-IND48VLT(-D): 7.88x3x1.75 in (200x76x44 mm)
- E-5D-IND48VLTB(-D): 7.88x3x1.75 in (200x76x44 mm)
- E-5D-IND48VLT-48V: 10.6x3.1x1.75 in (269x79x44 mm)
- E-5D-IND48VLTB-IND: 10.6x3.1x1.75 in (269x79x44 mm)
- Optional 1RU rackmount kit available (E-RK1-5D(BIND))
- The ENVIROMUX system can be mounted so that the sensor connectors are facing the front or back of the rack.
- E-5D-IND48VLT: 1.0 lb (0.45 kg)
- Operating temperature:
- E-5D-IND48VLT: 32 to 140˚F (0 to 60˚C)
- E-5D-IND48VLTB: 32 to 104˚F (0 to 40˚C)
- E-5D-IND48VLTB-IND: 32 to 140˚F (0 to 60˚C)
- E-5D-IND48VLT-INDLT/IND48VLT: -40 to 185˚F (-40 to 85˚C)
- Storage temperature:
- E-5D-IND48VLT: -22 to 140˚F (-30 to 60˚C)
- E-5D-IND48VLT-INDLT/IND48VLT: -40 to 185˚F (-40 to 85˚C)
- Operating /Storage Relative Humidity: 15 to 90% non-condensing RH.
- CE, RoHS
- Two years
Data Sheet:
Medium Enterprise Environment Monitoring System
Alert & Communication Accessories
Motion/Intrusion/Vibration Sensors
How To:
Locating OIDs Using a MIB Browser
How to Send SMS Messages to 18-34 Users
How to Install Console Drivers on Windows 8 Computer for E-5D-IND48VLT
How to Use LDAP Server with the E-5D-IND48VLT
How To Setup Syslog in an ENVIROMUX Enterprise Environment Monitoring System
How to Restore Defaults via RS232
How to Create an x.509 Certificate
How to Install E-LD to E-xD Using Connection to USB Console
User Manual:
Reasons To Buy an NTI Product