This NTI E-2D-POE Small Enterprise Environment Monitoring System, Power over Ethernet (PoE) monitors critical environmental conditions (such as temperature, humidity, and water leakage) that could destroy network components in your server room. When a sensor goes out of range of a configurable threshold, the system will notify you via email, SNMP traps, web-page alerts, a visual indicator (red LED), voice phone calls (via Automatic Voice Dialer System), and SMS messages (via email-to-SMS or external USB modem).
The system supports two external configurable sensors, five digital input sensors, and one output relay for control of external devices.
NTI E-2D-POE Small Enterprise Environment Monitoring System, Power over Ethernet (PoE) Features:
- Monitor and manage server room environmental conditions over IP.
- Sensors supported by a single E-2D:
- 2 external configurable sensors
- 5 digital inputs sensitive to contact closure
- 8 Remote Temperature/Humidity Sensors over IP
- E-MICRO-TRH(P): 1 integrated temperature/humidity combination sensor, 2 RJ45 ports for external temperature/humidity sensors, 2 digital inputs sensitive to contact closure, optional built-in Power over Ethernet (POE), dual DC power.
- 4 Remote 1-Wire Sensors over IP
- E-1W(P): two RJ11 connectors for daisy chaining many 1-wire temperature/humidity/dew point, thermocouple, or digital input expanders in any combination (up to 24 single-reading 1-wire sensors); two digital inputs sensitive to contact closure; dual DC power; optional Power over Ethernet (POE).
- Use an RJ45 RS485 Sensor Expander to add 8 RJ45 RS485 sensors.
- Use a Digital Input/Output Expander to add 16 digital inputs and 16 digital outputs.
- One output relay for control of external devices.
- Relay activates upon alarm or via the user interface.
- Control output relays via SNMP SET commands to power on/off external devices.
- Supports NTI's IP network video cameras for live view of any facility.
- One integrated view – see different Web cameras side-by-side with physical and environmental parameters.
- Any programmed event can trigger a snapshot from an IP camera.
- Monitor (ping) up to 64 IP network devices.
- Alerts are sent if devices are not responding.
- Linux inside.
- Create multiple alerts for any installed sensor.
- Sensor conditions (events) can be configured to trigger alerts by themselves, and/or be used in combination with other events to trigger Smart Alerts.
- Configure up to 50 events.
- Setup SSH commands to be sent when events are triggered to soft shutdown or reboot machines.
- Up to 20 Smart Alerts can be configured to use different event combinations to send alert messages.
- Configure up to 50 events.
- Alerts are posted in message log, which is accessible through Web user interface.
- Automatically configures network settings received from a connected DHCP server.
- If a DHCP server is not found, the default static IP address will be used.
- Integrates with various Open Source monitoring packages – Nagios and MRTG.
- The unit can be polled via SNMP.
- Two USB ports for connecting USB modem or for downloading log data to USB flash drive, and one USB console port for serial terminal interface.
- Available with optional internal battery backup.
- Alerts are sent when there is a power outage and when power returns.
- Available with optional built-in Power over Ethernet (PoE) or 24VDC power.
- Up to five units can be used together to increase the number of sensors connected.
- Cascade up to four E-2D/5D/16D units as slaves to one E-2D/5D/16D master unit via Ethernet connection.
- Each master and slave unit needs its own unique IP address.
- Uses a single Web interface for all systems/sensors connected.
- Cascade up to four E-2D/5D/16D units as slaves to one E-2D/5D/16D master unit via Ethernet connection.
- Dual redundant power supplies for connection to two separate power sources.
- The second power supply is sold separately.
- Optional industrial small environment monitoring system for high temperature environments. This industrial system has the ability to operate and monitor in harsh environments at high temperatures up to 167°F (75°C).
- Optional Self-Hosted Enterprise Environment Monitoring System Management Software for monitoring and configuring up to 3,000 E-2D/5D/16D devices and all connected sensors. Access from anywhere using a web browser on a computer, smartphone, and/or tablet. No clients or special apps to install.
- Flexible Zero-RU mounting.
- Mounting tabs included.
- Optional 1RU rackmount kit available; the ENVIROMUX unit can be mounted with the front or rear facing out.
- Optional DIN mounting available.
- Security: HTTPS, SSHv2, SSLv3, IP Filtering, LDAPv3, AES 256-bit encryption, 16-character username/password authentication, user account restricted access rights.
- Multi-language support – English, German, Chinese, and Japanese.
- Use in data centers, co-lo sites, web hosting facilities, telecom switching sites, POP sites, server closets, or any unmanned area that needs to be monitored.
- Use the E-2D with a wireless router and Wi-Fi Range Extender to create a Wireless Environment Monitoring System.
- Configure, monitor, and receive alerts without the use of a wired network connection
Why not buy this NTI E-2D-POE Small Enterprise Environment Monitoring System, Power over Ethernet (PoE) today?
NTI E-2D-POE Small Enterprise Environment Monitoring System, Power over Ethernet (PoE) Specifications:
RJ45 Sensor Ports
- Two female RJ45 jacks for connecting NTI temperature, humidity, liquid detection, smoke detection, glass break, vibration, motion sensors, and more.
- Two levels of user-defined alerts – non-critical and critical.
- Provides +12 VDC, 100 mA for each port.
Dry Contact Closures
- Five screw terminal pairs for connecting dry contact devices and the liquid detection sensor.
- Potential-free.
- Output voltage: +5 V DC
- Current limited to 10 mA
- Maximum resistance to close contact: 300K Ohm
Output Relay
- One screw terminal pair.
- Potential-free relay switch contacts.
- Normally open / normally closed connection points.
- Maximum switching load: 1A at 125VAC or 30VDC.
USB Ports
- Two female USB Type A connectors for connecting USB modem or for downloading log data to USB flash drive.
- One female USB Type B connector for connecting a PC for serial terminal access.
Ethernet Port
- One female RJ45 connector.
- 10/100 Base-T Ethernet interface.
- Supports full- and half-duplex.
Power Output
- AUX Power
- One screw terminal pair.
- Provides +12 VDC, 500 mA.
Optional Back-Up Battery
- Rechargeable sealed lithium battery.
- Provides back-up for two hours.
MTBF
- E-2D: 229,580 hours.
- E-2DB: 230,693 hours.
Protocols
- HTTP/HTTPS, SNMP V1/V2c/V3, SMTP, TCP/IP, Syslog, SNTP, DHCP, SSHv2, SSLv3, TLS v1.2, LDAPv3, XOAUTH2, AES 256-bit, 3DES, Blowfish, RSA, EDH-RSA, Arcfour, IPV6, WAP 2.0, RADIUS
- Support for XOAUTH2 provides higher security authentication for email accounts (e.g. Gmail).
- Compatible with any SNMP management software.
- The unit can be polled via SNMP.
- Operates and configures via HTTP/HTTPS web page, Telnet, SSH, or USB serial interface.
- Supports Internet Explorer 6.0 and higher, Firefox 1.5 and higher, Netscape 9, Google Chrome, Safari 1.3 and higher for MAC, and Safari 3.0 and higher for PC.
- Multiplatform support: Windows 7/8/10, Windows Server 2008/2012/2016/2019, Solaris, Linux, FreeBSD, and MAC OS 10/11.
- An IP address can be assigned to the E-2D automatically by a DHCP server.
- Generates SNMP traps, email alerts, syslog messages, and SMS messages (via USB 3G modem).
- Alerts are posted in event log, which is accessible through Web user interface.
- Email alerts can be sent to 17 addresses.
- Supports HTTP REST API to poll sensor data with response in JSON format.
Dimensions
- WxDxH: 5.82x3x1.75 in (148x76x44 mm)
- Optional 1RU rackmount kit available
(E-RK1-2D).- The ENVIROMUX system can be mounted so that the sensor connectors are facing the front or back of the rack.
Weight
- E-2D: 1.0 lb (0.45 kg)
Power
- Dual DC power.
- If the first power source fails, the unit will automatically, without interruption, switch over to the second power source before switching to the optional battery backup.
- 100 to 240 VAC at 50 or 60 Hz via AC adapter.
- Includes one country-specific AC adapter. The second AC adapter is sold separately.
- Power consumption: 10W.
- Optional built-in Power over Ethernet (PoE)
- Power over Ethernet standards supported: IEEE 802.3af, 802.3at.
- Proprietary schemes such as Cisco Discovery Protocol are not supported.
- Similar legacy switches and routers will have to use PWR-SPLY-9V3A
- Proprietary schemes such as Cisco Discovery Protocol are not supported.
- If the Power over Ethernet source fails, the unit will automatically, without interruption, switch over to the DC power source.
- Power over Ethernet standards supported: IEEE 802.3af, 802.3at.
- Optional 24VDC power.
- Accepts 9~36VDC (24VDC nominal).
- For installation in a 24V Telecom environment.
- Use the PWR-48V-12V1-6A DC-DC power converter to install the E-2D in a 48V or 24V Telecom environment.
Environmental
- Operating temperature:
- E-2D: 32 to 140°F (0 to 60°C)
- E-2D-IND: -4 to 167°F (-20 to 75°C)
- Storage temperature: -22 to 140°F (-30 to 60°C).
- Operating/Storage Relative Humidity: 5 to 90% non-condensing RH.
Regulatory Approvals
- CE, RoHS
- EN51055, EN50121-3-2
Warranty
- Two years
Why not buy this NTI E-2D-POE Small Enterprise Environment Monitoring System, Power over Ethernet (PoE) today?