NTI E-16D Large Enterprise Environment Monitoring System, AC Power

NTI

$1,315.00

5% Discount. Apply Code 5percentOff at Checkout!

Part Number:
E-16D
Availability:
In Stock
1:
16 External Configurable Sensors
2:
8 Digital Inputs Sensitive To Contact Closure
3:
Configure up to 50 Events
4:
Free 15-Day Trial (See below FAQ)
5:
Free Shipping
6:
2-Year NTI Warranty
ADD OPTIONS:
NTI E-16D Large Enterprise Environment Monitoring System, AC Power

This NTI E-16D Large Enterprise Environment Monitoring System, AC Power monitors critical environmental conditions, such as temperature, humidity, liquid water presence, power, intrusion, and smoke. When a sensor goes out of range of a configurable threshold, the system will notify you via email, LEDs, alarm beacon, siren, web page, network management (SNMP), voice phone calls (via Automatic Voice Dialer System), and SMS messages (via email-to-SMS or external USB modem).

The system includes three internal sensors: temperature, humidity and power. It also supports 16 external configurable sensors, eight digital input sensors, and four output relays for control of external devices

NTI E-16D Large Enterprise Environment Monitoring System, AC Power Features:

  • Monitor and manage server room environmental and security conditions over IP.
  • Sensors supported by a single E-16D:
    • 16 external configurable sensors
    • 8 digital inputs sensitive to contact closure
    • 3 internal sensors – temperature, humidity, power
    • 8 Remote Temperature/Humidity Sensors over IP
      • E-MICRO-TRH(P): 1 integrated temperature/humidity combination sensor, 2 RJ45 ports for external temperature/humidity sensors, 2 digital inputs sensitive to contact closure, optional built-in Power over Ethernet (POE), dual DC power.
    • 4 Remote 1-Wire Sensors over IP
      • E-1W(P): two RJ11 connectors for daisy chaining many 1-wire temperature/humidity/dew point, thermocouple, or digital input expanders in any combination (up to 24 single-reading 1-wire sensors); two digital inputs sensitive to contact closure; dual DC power; optional Power over Ethernet (POE).
    • Use an RJ45 RS485 Sensor Expander to add 8 RJ45 RS485 sensors.
    • Use a Digital Input/Output Expander to add 16 digital inputs and 16 digital outputs.
  • Four output relays for control of external devices.
    • Relay activates upon alarm or via the user interface.
    • Control output relays via SNMP SET commands to power on/off external devices.
  • Supports NTI's IP network video cameras for live view of any facility.
    • One integrated view – see different Web cameras side-by-side with physical and environmental parameters.
    • Any programmed event can trigger a snapshot from an IP camera.
  • Monitor (ping) up to 64 IP network devices.
    • Alerts are sent if devices are not responding
  • Linux inside.
  • Create multiple alerts for any installed sensor.
  • Sensor conditions (events) can be configured to trigger alerts by themselves, and/or be used in combination with other events to trigger Smart Alerts.
    • Configure up to 50 events.
      • Setup SSH commands to be sent when events are triggered to soft shutdown or reboot machines.
    • Up to 20 Smart Alerts can be configured to use different event combinations to send alert messages.
  • View entries stored in the system logs.
    • Event log records system events such as alerts, user login/logout, failed email messages, etc.
    • Data log records samples of sensor readings. User specified sampling time period.
    • With E-16D, up to 1,724 data log entries and 1,000 event log entries are stored.
    • With E-16DEL, up to 1,200,000 data log entries and 3,000 event log entries are stored.
      • 256 MB non-volatile memory - both the data log and event log persist after power cycle.
  • Automatically configures network settings received from a connected DHCP server.
    • If a DHCP server is not found, the default static IP address will be used.
  • Integrates with various Open Source monitoring packages - Nagios and MRTG.
    • The unit can be polled via SNMP.
  • USB ports for connecting USB modem or for downloading log data to USB flash drive.
  • Internal battery backup.
    • Alerts are sent when there is a power outage and when power returns.
  • Available with optional dual power for connection to two separate power sources.
  • Up to five units can be connected via Ethernet connection or using CAT5 expansion cables to increase the number of sensors connected.
    • Cascade up to four E-2D/5D/16D units as slaves to one E-2D/5D/16D master unit via Ethernet connection.
      • Each master and slave unit needs its own unique IP address.
    • Cascade up to four E-16D units as slaves to one E-16D master unit using CAT5/5e/6 patch cables with RJ45 connectors wired straight through.
      • Each slave unit needs its own unique RS485 address value that can range from 1-255.
    • Uses a single Web interface for all systems/sensors connected.
  • Available with optional 48VDC or 24VDC power.
  • Optional Self-Hosted Enterprise Environme nt Monitoring System Management Software for monitoring and configuring up to 3,000 E-2D/5D/16D devices and all connected sensors. Access from anywhere using a web browser on a computer, smartphone, and/or tablet. No clients or special apps to install.
  • 1RU rack mount case is standard.
    • The ENVIROMUX system can be mounted so that the sensor connectors are facing the front or back of the rack.
  • Security: HTTPS, SSHv2, SSLv3, IP Filtering, LDAPv3, AES 256-bit encryption, 16-character username/password authentication, user account restricted access rights.
  • Multi-language support – English, German, Chinese, and Japanese.
  • Use in data centers, co-lo sites, web hosting facilities, telecom switching sites, POP sites, server closets, or any unmanned area that needs to be monitored.
  • Use the E-16D with a wireless router and Wi-Fi Range Extender to create a Wireless Environment Monitoring System.
    • Configure, monitor, and receive alerts without the use of a wired network connection

Why not buy this NTI E-16D Large Enterprise Environment Monitoring System, AC Power today?

NTI E-16D Large Enterprise Environment Monitoring System, AC Power Specifications:

1. Power Port

  • 100 to 240 VAC at 50 or 60 Hz via IEC connector. (Country-specific power supply cable included.)
  • Power consumption: 35W
  • Connection for Earth Ground.
  • Fuse protection.
  • Optional 48VDC power (not shown).
    • Accepts 36~72VDC (48VDC nominal).
  • Optional 24VDC power (not shown).
    • Accepts 20~32VDC (24VDC nominal).
  • Optional dual power (not shown).
    • Available on AC, 48VDC, and 24VDC models.
    • If the first power source fails, the unit will automatically, without interruption, switch over to the second power source before switching to the battery backup.

2. RJ45 Sensor Ports

  • Sixteen RJ45 modular jacks for connecting NTI temperature, humidity, temperature/humidity, liquid detection, smoke detection, glass break, vibration and motion sensors.

3. Digital Inputs

  • Eight screw terminals pairs for connecting dry contact devices.
  • Input voltage: 0VDC to +25VDC.
  • Provides +12VDC, 50mA for terminals 1-7, and +12VDC, 350mA for terminal 8 only.
  • Fuse protection.

4. Digital Outputs

  • Four screw terminals pairs.
  • Potential-free relay switch contacts.
  • Normally open / normally closed connection points.
  • Maximum switching load: 0.5A at 100VAC, 1A at 30VDC, 0.5A at 48VDC.

5. Beacon Port

  • One screw terminal pair.
  • Provides +12VDC, 180 mA to supply an alarm beacon.
  • Fuse protection

6. Siren Port

  • One screw terminal pair.
  • Provides +12VDC, 180 mA to supply a siren.
  • Fuse protection

7. AUX Power

  • One screw terminal pair.
  • Provides 12VDC, 150mA.

8. USB Device Ports

  • Four female USB Type A connectors for connecting USB modem or for downloading log data to USB flash drive.
    • Two USB ports on front panel and 2 on back panel.

9. USB Console Port

  • One female USB Type B connector for connecting a PC for serial terminal access.

10. RS232 (DCS) Port

  • One female RJ45 serial port for terminal access.

11. Ethernet Port

  • One 10/100 Base-T Ethernet port with RJ45 Ethernet connector.
    • Supports full- and half-duplex.

12. RS232 AUX Port

  • One RJ45 port for connecting a serial GSM modem or a remote serially-controlled device.

13. Cascade In/Out Ports

  • Two RJ45 jacks.
  • A maximum of 5 systems can be used in a cascaded configuration via RS485 to increase the number of sensor ports (1 master, 4 slaves).
    • Each slave unit needs its own unique RS485 address value that can range from 1-255.
    • Use CAT5/5e/6 patch cables with RJ45 connectors wired straight through
    • Up to 4,000 feet between the master unit and the slave unit.
    • The last slave must have a terminating plug (E-TRMPLG, not included) in the empty socket.
  • Uses a single Web interface for all systems connected

Why not buy this NTI E-16D Large Enterprise Environment Monitoring System, AC Power today?

E-16D USER Manual

E-16D Data Sheet

Why not buy this NTI E-16D Large Enterprise Environment Monitoring System, AC Power today?