Kramer BCLS-23GR-5 CAT 6 F/UTP 23AWG 400MHz Bulk Cable - Low Smoke & Halogen Free
Kramer BCLS-23GR-5 CAT 6 F/UTP 23AWG 400MHz Bulk Cable - Low Smoke & Halogen Free
is a high-performance CAT 6 F/UTP cable designed for IT, LAN and Ethernet installations. The cable is constructed with 23AWG solid bare copper conductors with a cross filler and overall metal foil screen with a drain wire. It is enclosed in an LSZH jacket with sequential markings every meter and packed on a fumigated plywood reel. BCLS-23 cable exceeds CAT 6 specifications to provide additional performance and bandwidth beyond the basic standard.
Kramer BCLS-23GR-5 CAT 6 F/UTP 23AWG 400MHz Bulk Cable - Low Smoke & Halogen Free
- High-Performance Transmission.
- High-Quality Safety Properties.
- Sweep Frequency up to 400MHz.
Why not buy this Kramer BCLS-23GR-5 CAT 6 F/UTP 23AWG 400MHz Bulk Cable - Low Smoke & Halogen Free today?
Kramer BCLS-23GR-5 CAT 6 F/UTP 23AWG 400MHz Bulk Cable - Low Smoke & Halogen Free
- CONSTRUCTION
- Conductor: 4 pairs of 23AWG solid bare copper
- Insulation: Polyolefin (PO)
- Insulation: blue & white/blue stripe, orange & white/orange stripe, green & white/green stripe, brown & white/brown stripe
- Twist: Left-hand
- Assembly: Left hand direction
- Rip Shield: Mylar tape
- Drain Wire: 24AWG solid tinned copper
- Shield: Al Mylar tape, 100% coverage and mylar side facing out
- Jacket: Low smoke zero halogen (LSZH), green (Pantone 7732C)
- FILLER: Polyolefin (PO)
- DIAMETERS
- Jacket: Diameter: 7.2 ±0.2mm
- Jacket: thickness: 0.45 ±0.05mm
- Insulation: Blue & white/blue stripe: 1.08 ± 0.02mm
- Insulation: Orange & white/orange stripe: 1.05 ± 0.02mm
- Insulation: Green & white/green stripe: 1.08 ± 0.02mm
- Insulation: Brown & white/brown stripe: 1.05 ± 0.02mm
- ELECTRICAL
- Temperature & Voltage Rating: 60˚C @300V
- Spark Test: 2.5kV DC
- AC Leakage Current: ≤10mA (1.5kV AC) through overall jacket
- Conductor DC Resistance: ≤9.38? /100m
- Resistance Unbalance: ≤5%
- Dielectric Strength: 1.5kV AC for 2sec
- Insulation Resistance: ≥5000M? /m
- Mutual Capacitance: ≤5.6nF /100m
- Capacitance Unbalance: ≤330pF /100m pair-to-ground
- Characteristic Impedance: 100±15? @1~100MHz
- Coupling Attenuation: ≤55dB @30MHz, ≤47dB @250MHz
- USAGE AND ENVIRONMENTAL
- Cable Cold Bend: -20˚C for 4hr
- Insulation Tensile Strength: 2400 PSI min. (1.69kg/m.sq)
- NVP: 69%
- Temperature Range: Storage & shipping: -20˚C to 60˚C
- Temperature Range: installation: 0˚C to 60˚C
- Temperature Range: operation: -20˚C to 60˚C
- Minimum Bending Radius: ≥ 4 times of overall diameter
- Maximum Pulling Tension: ≤110N
- REGULATORY PERFORMANCE
- ANSI/TIA-568-C.2 (2009): Balanced Twisted-Pair Telecommunications Cabling and Components Standards
- ISO/IEC 11801 (Edition 2.2): Information technology - Generic cabling for customer premises
- IEC 61156-5 (Edition 2.0): Multicore and symmetrical pair/quad cables for digital communications - Part 5: Symmetrical pair/quad cables with transmission characteristics up to 1000 MHz - Horizontal floor wiring - Sectional specification
- EN 50288-6-1:2013: Multi-element metallic cables used in analogue and digital communication and control - Part 6-1: Sectional specification for unscreened cables characterized up to 250MHz - Horizontal and building backbone cables
- EN 50173-12011: Information technology. Generic cabling systems. General requirements
- REGULATORY SAFETY
- IEC 60332-1-2: Tests on electric and optical fiber cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1kW pre-mixed flame
- IEC 61034-1 / 61034-2: Measurement of smoke density of cables burning under defined conditions
- IEC 60754-2: Test on gases evolved during combustion of materials from cables