Kramer BCLS-11GY-3 CAT 5E U/UTP 24AWG 350MHz Bulk Cable

Kramer

Price: $178.00
Today's Price: $142.40

10% Discount. Apply Code 10percentOff at Checkout!

Part Number:
BCLS-11GY-3
UPC:
7291063073343
Availability:
In Stock
1:
CAT 5E U/UTP, 24AWG solid bare copper
2:
LSZH, With rip cord
3:
Free Shipping
10:
Free1-Year Kramer Warranty
4:
Free Lifetime Telephone, CHAT, Text, Fax & Email Tech Support
Kramer BCLS-11GY-3 CAT 5E U/UTP 24AWG 350MHz Bulk Cable - Low Smoke & Halogen Free

Kramer BCLS-11GY-3 CAT 5E U/UTP 24AWG 350MHz Bulk Cable - Low Smoke & Halogen Free
is a high-performance CAT 5E U/UTP cable designed for IT, LAN and Ethernet installations. BCLS-11 is constructed with four pairs of 24AWG solid bare copper conductors in an LSZH jacket with internal rip cord and sequential markings every meter. It is packed in a Reelex II carton for easy to pull-out. BCLS-11 exceeds CAT 5E specifications to provide additional performance and bandwidth beyond the basic standard.

Kramer BCLS-11GY-3 CAT 5E U/UTP 24AWG 350MHz Bulk Cable - Low Smoke & Halogen Free

  • High-Performance Transmission.
  • High-Quality Safety Properties.
  • Sweep Frequency up to 350 MHz.
  • Length - Available in Reelex II Cartons of 305m (1000ft).

Why not buy this Kramer BCLS-11GY-3 CAT 5E U/UTP 24AWG 350MHz Bulk Cable - Low Smoke & Halogen Free today?

Kramer BCLS-11GY-3 CAT 5E U/UTP 24AWG 350MHz Bulk Cable - Low Smoke & Halogen Free

  • CONSTRUCTION
    • Conductor: 4 pairs of 24AWG solid bare copper
    • Insulation: Polyolefin (PO), blue & white/blue stripe, orange & white/orange stripe, green & white/green stripe, brown & white/brown stripe
    • Twist: Conductors: left-hand, assembly: left-hand
    • Rip Cord: Polyester multi-yarn
    • Jacket: Low smoke zero halogen (LSZH), gray (Pantone 427C)
  • DIAMETERS
    • Jacket: Diameter: 4.9 ±0.2mm, thickness: 0.50 ±0.05mm
    • Conductors: 0.87mm (0.034") ±0.02mm (0.001")
  • ELECTRICAL
    • Temperature & Voltage Rating: 60˚C @300V
    • Spark Test: 2.5kV DC
    • AC Leakage Current: ≤10mA (1.5kV AC) through overall jacket
    • Coupling Attenuation: ≤55dB @30MHz, ≤55dB @100MHz
    • Conductor DC Resistance: ≤9.38? /100m
    • Resistance Unbalance: ≤5%
    • Dielectric Strength: 1.5kV AC for 2sec
    • Insulation Resistance: ≥5000M? /m
    • Mutual Capacitance: ≤5.6nF /100m
    • Capacitance Unbalance: ≤330pF /100m pair-to-ground
    • Characteristic Impedance: 100±15? @1~100MHz
    • Coupling Attenuation: ≤55dB @30MHz, ≤55dB @100MHz
  • USAGE AND ENVIRONMENTAL
    • Cable Cold Bend: -20˚C for 4hr
    • Insulation Tensile Strength: 2400 PSI min. (1.69kg/m.sq)
    • NVP: 71%
    • Temperature Range: Storage & shipping: - 20˚C to 60˚C, installation: - 0˚C to 60˚C, operation: - 20˚C to 60˚C
    • Minimum Bending Radius: ≥4 times of overall diameter
    • Maximum Pulling Tension: ≤110N
  • REGULATORY PERFORMANCE
    • ANSI/TIA-568-C.2 (2009): Balanced Twisted-Pair Telecommunications Cabling and Components Standards
    • ISO/IEC 11801 (Edition 2.2): Information technology - Generic cabling for customer premises
    • IEC 61156-5 (Edition 2.0): Multicore and symmetrical pair/quad cables for digital communications - Part 5: Symmetrical pair/quad cables with transmission characteristics up to 1000 MHz - Horizontal floor wiring - Sectional specification
    • EN 50288-3-1 2013: Multi-element metallic cables used in analogue and digital communication and control sectional specification for unscreened cables characterized up to 100 MHz. horizontal and building backbone cables
  • REGULATORY SAFETY
    • EN 50173-1 2011: Information technology - Generic cabling systems - Part 1: General requirements
    • IEC 60332-1-2: Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
    • IEC 61034-1 / 61034-2: Measurement of smoke density of cables burning under defined conditions
    • IEC 60754-2: Test on gases evolved during combustion of materials from cables